HRS Process Systems
part of HRS Group
© 2012
Home
>
Case Studies
>
Ecoflux Case Studies
>
Case Study 2
About us
Products
Applications
Case Studies
Resources
Company Information
Vision and Mission
Quality Policy
Certifications
Write To Us
Ecoflux* Corrugated Tube Heat Exchanger
Ecoflux* Smooth Tube Heat Exchangers
Plate Heat Exchangers
Unicus(R) Scraped Surface Heat Exchanger
Food Systems
Hygienic Piston Pumps
Aseptic Fillers
Overview
Technology
Advantages
Corrugated Tube Types
Models
Design
Construction
Comparison
Overview
Design
Advantages
PHE Types
PHE Models & Dimensions
Brazed PHE
Overview
Technology
Advantages
Design
Construction
Food Processing
Overview
Models
Features
Ecoflux* Corrugated Tube Heat Exchanger
Ecoflux* Smooth Tube Heat Exchangers
Plate Heat Exchangers
Unicus(R) Scraped Surface Heat Exchanger
Food Systems
Hygienic Piston Pumps
Aseptic Fillers
Generic
Industry
Product
Industry
Product
Ecoflux Case Studies
Case Study 1
Case Study 2
Case Study 3
Enquiry
Photo Gallery
News & Events
Careers
Downloads
FAQs
Ecoflux
Unicus
Hygienic Piston Pumps
Aseptic Fillers
Plate Heat Exchangers
Sitemap
HRS Group
Testimonials
News & Events
Contact Us
Case Studies
Ecoflux
-
Case Study 1
-
Case Study 2
-
Case Study 3
Contact Us
Tel. +91 20 2566 3581/82
Fax. +91 20 2566 3583
Email:
info@hrsasia.co.in
Case Studies > Ecoflux
*
Corrugated Tube Heat Exchanger >
Case 2
Thermic Fluid Cooling Application
Shell & Tube Heat Exchanger Versus Ecoflux *Corrugated Tube Heat Exchangers
Process Parameters
Units
Shell Side
Tube Side
Thermic Fluid Cooler
Fluid
--
Water
Marlotherm - X
Flow Rate
kg / hr
54313
104500
Temperature
In / Out °C
35 / 39
49.4 / 44.6
Heat Load
kcal / hr
217775
217775
Allowable Pressure Drop
kg / cm2
0.1
0.1
Fouling Factor
hr.m2.°C/kcal
0.0001
0.0002
Inlet Pressure
kg / cm2
3.0
2.0
Design Pressure
kg / cm2
5
5
Design Temperature
°C
70
100
Test Pressure
kg / cm2
7.5
7.5
Details Of Heat Exchanger
Shell & Tube
Cthe
No Of Tubes
nos.
126
169
Tube O.D.
mm
25.4
18
Tube Thickness
mm
1.62
0.70
Tube Length
mm
6000
3000
Heat Transfer Area
m2
59
28.7
Shell I.D.
mm
489
323
Shell MOC
--
SA 515 GR 60
SA 515 GR 60
Tube MOC
--
SA 179
SS 304
No Of Passes
nos.
2
1
Fluid Velocity In Shell
m / s
0.35
0.42
Fluid Velocity In Tube
m /s
1.35
0.93
Baffles
nos
Provided (18)
Not Required
Actual Pressure Drop
Shell Side
kg / cm2
0.10
0.006
Tube Side
kg / cm2
0.20
0.03
Heat Trf. Coefficient
Design
kcal / hr.m2.°C
378
759
Clean
kcal / hr.m2.°C
547
987
Area Reduction
%
--
52
*
Submitted for Registration
Home
|
Products
|
Careers
|
Contact Info
|
Write To Us
|
Sitemap
2012 - Copyright HRS Process Systems Ltd., India.
Visitors: